Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 249: 123662, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35691129

RESUMO

Non-thermal plasma-based ionization sources have been widely used and shown excellent soft ionization performance in mass spectrometry. Despite their extensive application, the ionization mechanisms of these sources are of great interest for further exploring their full potential. A controlled atmosphere can provide a clean and controllable ionization environment and is beneficial for studying the ionization mechanism. The plasma source itself also has a significant impact on the ionization mechanism of the analyte, and the voltage waveform is one of the key parameters for controlling the plasma source. In this paper, a miniature flexible micro-tube plasma (FµTP) ionization source was sustained using both square and sine-wave voltage. The ionization processes of typical semi-fluorinated n-alkanes (SFAs) were investigated in the controlled atmosphere filled with 80% N2 and 20% O2. The main mass peaks using both square and sine-wave voltages are found to be [M-mH]+ and [M-mH+nO]+ (m = 1, 3; n = 0, 1, 2). However, for the square-wave voltage, the [M-H+O]+ species are the most abundant while [M-H]+ species are dominant for the sine-wave voltage, showing that the plasma generated with sine-wave voltage is somewhat "softer" than the one with square-wave voltage for SFAs. With the assistance of optical spectroscopy, the plasma developments in one discharge cycle for both voltage waveforms were obtained. Only one discharge can be found in each half cycle for square-wave voltage while several for the sine-wave voltage. These would be responsible for the different ionization behaviors in these two cases. This work provides more insight into the ionization mechanism of SFAs and more understanding of plasma-based soft ionization. In addition, the analytical performance was evaluated to be comparable when using these two voltage generators with a big difference in cost, which will benefit the instrumental development.


Assuntos
Alcanos , Atmosfera , Espectrometria de Massas , Plasma , Análise Espectral
2.
J Am Soc Mass Spectrom ; 33(1): 45-53, 2022 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-34856796

RESUMO

An ambient air laser desorption, plasma ionization imaging method is developed and presented using a microsecond pulsed laser diode for desorption and a flexible microtube plasma for ionization of the neutral desorbate. Inherent parameters such as the laser repetition rate and pulse width are optimized to the imaging application. For the desorption substrate, copper spots on a copper-glass sandwich structure are used. This novel design enables imaging without ablating the metal into the mass spectrometer. On this substrate, fixed calibration markers are used to decrease the positioning error in the imaging process, featuring a 3D offset correction within the experiment. The image is both screened spot-by-spot and per line scanning at a constant speed, which allows direct comparison. In spot-by-spot scanning, a novel algorithm is presented to unfold and to reconstruct the imaging data. This approach significantly decreases the time required for the imaging process, which allows imaging even at decreased sampling rates and thus higher mass resolution. After the experiment, the raw data is automatically converted and interpreted by a second algorithm, which allows direct visualization of the image from the data, even on low-intensity signals. Mouse liver microtome cuts have been screened for dehydrated cholesterol, proving good agreement of the unfolded data with the morphology of the tissue. The method optically resolves 30 µm, with 30 µm diameter copper spots and a 10 µm gap. No conventional chemical matrices or vacuum conditions are required.

3.
Anal Chem ; 92(22): 15212-15220, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33135875

RESUMO

Ionization mechanisms of different lipid classes and other hydrophobic compounds have been evaluated in an ambient air laser-desorption flexible microtube plasma ionization (LD-FµTPi) setup, without sample manipulation. Lipids require a minimum laser fluency of 27 W/mm2 for efficient desorption and detection, providing the possibility for temperature-programmed laser desorption of different lipid classes. The flexible microtube plasma (FµTP) produces oxygen addition to double bonds, even to polyunsaturated molecules. The characteristic fragmentation pattern of phospholipids consisting of the neutral loss of the phosphocholine head group was verified. The formation of dimers due to hydrogen bonding and dispersion forces was observed as well. In this sense, soft ionization capabilities of the FµTP were proven in both ion modes. Ambient air mass spectrometry methods often suffer from decreased reproducibility, for instance, due to changing atmospheric conditions or sensitive positioning of the ion source. It was shown that neutrals become increasingly unstable above a distance of 7 ± 1 mm to the spectrometer's inlet, providing estimates for the free volume in LD-FµTPi MS. In this sense, no guided transport is required. The ion plume ejected from the plasma can be altered by applying a bias voltage to the copper substrate. Ions can be detected at -950 V, 300 V (negative ion mode) and -400 V, 900 V (positive ion mode), respectively. The ions are guided through an internal electric field gradient of the FµTP that arises from charged capillary walls, ideal for ion detection. In conclusion, this makes the method fast, robust, and flexible.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Lipídeos/análise , Lipídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Limite de Detecção , Oxigênio/química , Gases em Plasma/química
4.
Anal Chem ; 92(6): 4663-4671, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32106668

RESUMO

This study introduced sandwich-structured copper-glass substrates for standardization of laser desorption and plasma ionization. For standardized quantitative analysis, cavities were constructed which allow better reproducibility in droplet deposition and for laser application. Applying the diode laser, molten substrate material is incorporated into the glass, being trapped inside. Therefore, this method can be separated from laser ablation, achieving high ion signals without ablating material from the surface. Flexible microtube plasma (FµTP) was selected as the ionization source, this being the first time that laser desorption and FµTP ionization are coupled. This laser-plasma interface was applied to the detection of cholesterol, which showed a significantly improved limit of detection of 0.46 ng and linear dynamic range of 3 orders of magnitude in positive ion mode compared to other (ambient air mass spectrometry) methods. The main reason was the change of phase on the copper surface. The dehydrated molecule [M-H2O+H]+ was the base peak of the spectrum and no further dissociation or fragmentation was observed. Blood plasma was spiked with cholesterol. In a 1:100 chloroform dilution, the presence of the plasma was neglectable and led to the same detection limits and linear dynamic range as in the cholesterol standard. No sample preparation or internal standards were needed for calibration. The physical effects of the surface modification were investigated, including the calculation of the laser beam waist to simplify the comparison and reproducibility of results.


Assuntos
Colesterol/sangue , Cobre/química , Lasers , Colesterol/normas , Cobre/normas , Vidro/química , Vidro/normas , Humanos , Lasers/normas , Estrutura Molecular , Tamanho da Partícula , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Propriedades de Superfície
5.
Anal Chem ; 91(5): 3733-3739, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30672695

RESUMO

Plasma sources in atmospheric pressure soft-ionization mass spectrometry have gained significant interest in recent years. As many of these sources are used under ambient air conditions, their interaction with the surrounding atmosphere plays an important role in the ionization pathway. This study focuses on the interaction between the plasma source and the surrounding atmosphere by connecting the plasma source to the mass spectrometer using a 2 mm ID closed reactant capillary supplied by a reactant gas up to 500 mL per minute to gain a controlled atmosphere. Different reactant gases (Ar, He, O2, and N2) and reactant gas mixtures are tested with regard to the DBDI performance and then used to improve the ionization efficiency. Tailoring the controlled atmosphere for a certain analyte, for example, perfluorinated compounds, leads to significantly improved limits of detection up to 2 ppb.

6.
Anal Chem ; 90(17): 10111-10116, 2018 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-30063325

RESUMO

Dielectric barrier discharges are used as soft ionization sources for mass spectrometers or ion mobility spectrometers, enabling excellent possibilities for analytical applications. A new robust and small-footprint discharge design, flexible microtube plasma (FµTP), developed as a result of ongoing miniaturization and electrode design processes, is presented in this work. This design provides major safety benefits by fitting the electrode into an inert flexible fused silica capillary (tube). Notably, in this context, the small discharge dimensions enable very low gas flows in the range of <100 mL min-1; portability; the use of hydrogen, nitrogen, and air in addition to noble gases such as helium and argon, including its mixtures with propane; and application in microchip environments. By coupling FµTP with gas chromatography/mass spectrometry, we show that the polarity principle of the new discharge design allows it to outperform established ionization sources such as dielectric barrier discharge for soft ionization (DBDI) and low-temperature plasma (LTP) at low concentrations of perfluoroalkanes in terms of sensitivity, ionization efficiency, chemical background, linear dynamic range, and limit of detection by a large margin. In negative ion mode, the limit of detection is improved by more than 3-fold compared with that of DBDI and by 8-fold compared with that of LTP. The protonation capability was evaluated by headspace measurements of diisopropyl methylphosphonate in positive ion mode, showing low fragmentation and high stability in comparison to DBDI and LTP.

7.
Anal Chem ; 88(9): 5003-8, 2016 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-27046293

RESUMO

An electron emitter as a soft atmospheric pressure chemical ionization source is presented, which operates at inner pressures of the device in the medium vacuum range (>10(-3) hPa). Conventional nonradioactive electron emitters require high vacuum (<10(-6) hPa) to prevent electrical sparkovers. The emitter presented here contains structural modifications of an existing setup, which inhibits electrical breakdowns up to 10(-2) hPa at 8 kV acceleration voltage. The increased inner pressure reduces the ionization efficiency until 10(-3) hPa-achievable without a turbomolecular pump-by 2% compared to high-vacuum conditions. This can be compensated with an increase of the electron source output. The functionality of this ion source is demonstrated with mass spectrometric and ion mobility measurements of acetone, eucalyptol, and diisopropyl methanephosphonate. Additional mass spectrometric measurements of 20 different organic compounds demonstrate the soft characteristics of this ionization source.

8.
Anal Chem ; 87(22): 11415-9, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26496892

RESUMO

The soft ionization ability based on plasma-jet protonation of molecules initiated by a dielectric barrier discharge ionization source (DBDI) is certainly an interesting application for analytical chemistry. Since the change of an applied sinusoidal voltage may lead to different discharge modes the applied discharge was powered by a square wave generator in order to get a homogeneous plasma. It is known that besides the protonation [M+H](+) of unpolar as well as some polar molecules the homogeneous DBDI can be used to ionize molecules directly [M](+). Here we prove that the DBDI can be applied to exchange fluorine by oxygen of perfluorinated compounds (PFC). PFC are organofluorine compounds with carbon-fluorine and carbon-carbon bonds only but no carbon-hydrogen bonds. While the position of the introduction into the plasma-jet is essential, PFC can be measured in the negative mass spectrometer (MS) mode.


Assuntos
Fluorocarbonos/análise , Fluorocarbonos/química , Cromatografia Gasosa/instrumentação , Espectrometria de Massas/instrumentação , Estrutura Molecular
9.
Small ; 10(14): 2870-6, 2014 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-24678019

RESUMO

The construction and operation of a low-cost plotter for fabrication of microarrays for multiplexed single-cell analyses is reported. The printing head consists of polymeric pyramidal pens mounted on a rotation stage installed on an aluminium frame. This construction enables printing of microarrays onto glass substrates mounted on a tilt stage, controlled by a Lab-View operated user interface. The plotter can be assembled by typical academic workshops from components of less than 15,000 Euro. The functionality of the instrument is demonstrated by printing DNA microarrays on the area of 0.5 cm2 using up to three different oligonucleotides. Typical feature sizes are 5 µm diameter with a pitch of 15 µm, leading to densities of up to 10(4)-10(5) spots/mm2. The fabricated DNA microarrays are used to produce sub-cellular scale arrays of bioactive epidermal growth factor peptides by means of DNA-directed immobilization. The suitability of these biochips for cell biological studies is demonstrated by specific recruitment, concentration, and activation of EGF receptors within the plasma membrane of adherent living cells. This work illustrates that the presented plotter gives access to bio-functionalized arrays usable for fundamental research in cell biology, such as the manipulation of signal pathways in living cells at subcellular resolution.


Assuntos
Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Análise de Célula Única/instrumentação , Análise Serial de Tecidos/instrumentação , Custos e Análise de Custo , Fator de Crescimento Epidérmico/metabolismo , Receptores ErbB/metabolismo , Humanos , Células MCF-7 , Técnicas Analíticas Microfluídicas/economia , Técnicas Analíticas Microfluídicas/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/economia , Impressão/instrumentação , Análise de Célula Única/economia , Análise Serial de Tecidos/economia , Interface Usuário-Computador
10.
Lab Chip ; 11(16): 2763-71, 2011 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-21709920

RESUMO

Spatially defined neuronal networks have great potential to be used in a wide spectrum of neurobiology assays. We present an original technique for the precise and reproducible formation of neuronal networks. A PDMS membrane comprising through-holes aligned with interconnecting microchannels was used during oxygen plasma etching to dry mask a protein rejecting poly(ethylene glycol) (PEG) adlayer. Patterns were faithfully replicated to produce an oxidized interconnected array pattern which supported protein adsorption. Differentiated human SH-SY5Y neuron-like cells adhered to the array nodes with the micron-scale interconnecting tracks guiding neurite outgrowth to produce neuronal connections and establish a network. A 2.0 µm track width was optimal for high-level network formation and node compliance. These spatially standardized neuronal networks were used to analyse the dynamics of acrylamide-induced neurite degeneration and the protective effects of co-treatment with calpeptin or brain derived neurotrophic factor (BDNF).


Assuntos
Bicamadas Lipídicas , Membranas Artificiais , Degeneração Neural , Rede Nervosa , Fármacos Neuroprotetores/farmacologia , Acrilamida/farmacologia , Adsorção , Fator Neurotrófico Derivado do Encéfalo/farmacologia , Diferenciação Celular/efeitos dos fármacos , Dimetilpolisiloxanos/química , Dipeptídeos/farmacologia , Humanos , Degeneração Neural/induzido quimicamente , Rede Nervosa/efeitos dos fármacos , Propriedades de Superfície
11.
Lab Chip ; 11(2): 231-7, 2011 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-20978708

RESUMO

We present a highly parallel microfluidic approach for contacting single cell pairs. The approach combines a differential fluidic resistance trapping method with a novel cellular valving principle for homotypic and heterotypic single cell co-culturing. Differential fluidic resistance was used for sequential single cell arraying, with the adhesion and flattening of viable cells within the microstructured environment acting to produce valves in the open state. Reversal of the flow was used for the sequential single cell arraying of the second cell type. Plasma stencilling, along the linear path of least resistance, was required to confine the cells within the trap regions. Prime flow conditions with minimal shear stress were identified for highly efficient cell arraying (∼99%) and long term cell culture. Larger trap dimensions enabled the highest levels of cell pairing (∼70%). The single cell co-cultures were in close proximity for the formation of connexon structures and the study of contact modes of communication. The research further highlights the possibility of using the natural behaviour of cells as the working principle behind responsive microfluidic elements.


Assuntos
Técnicas de Cocultura/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Análise de Célula Única/instrumentação , Análise Serial de Tecidos/instrumentação , Linhagem Celular , Linhagem Celular Tumoral , Técnicas de Cocultura/métodos , Desenho de Equipamento , Humanos , Técnicas Analíticas Microfluídicas/métodos , Análise de Célula Única/métodos , Análise Serial de Tecidos/métodos
12.
J Chromatogr A ; 1216(47): 8265-9, 2009 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-19631324

RESUMO

A novel free-flow electrophoresis glass chip design with two-depth etched structures for the separation and fractionation of proteins is presented. The microfluidic structures etched in two depths enhance the flow characteristics inside the miniaturized device. A novel nine-port outlet interface enables the fractionation of the separated analytes. The separation and focussing of a protein sample mixture demonstrated the ability of the new chip.


Assuntos
Eletroforese/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Proteínas/isolamento & purificação , Animais , Eletroforese/métodos , Desenho de Equipamento , Vidro , Cavalos , Técnicas Analíticas Microfluídicas/métodos , Microscopia Eletrônica de Varredura , Miniaturização , Mioglobina/isolamento & purificação , Propriedades de Superfície , Inibidores da Tripsina/isolamento & purificação
13.
Lab Chip ; 5(2): 205-11, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15672136

RESUMO

A new concept for continuous measurements on microchips is presented. A PMMA (polymethylmethacrylate) based capillary electrophoresis chip with integrated conductivity detection is combined with a second chip, which undertakes the task of fluid handling and electrical connections. The combination of electrokinetic and hydrodynamic flows allows long-term continuous stable analyses with good reproducibilities of migration time and peak heights of analytes. The two-chip system is characterized in terms of stability and reproducibility of separation and detection of small ions. Relative standard deviations of <1% and 3% respectively for retention times and peak heights during long-term measurements can be achieved. The new system combines simple handling and automated analysis without the need for refilling, cleaning or removal of the separation chip after one or several measurements.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...